Voici les éléments 1 - 10 sur 91
Vignette d'image
Publication
Accès libre

A cold-atom Ramsey clock with a low volume physics package

2024-01-09, Alan Bregazzi, Batori, Etienne, Affolderbach, Christoph, Mileti, Gaetano, Paul Griffin, Ben Lewis, Erling Riis

We demonstrate a Ramsey-type microwave clock interrogating the 6.835~GHz ground-state transition in cold \textsuperscript{87}Rb atoms loaded from a grating magneto-optical trap (GMOT) enclosed in an additively manufactured loop-gap resonator microwave cavity. A short-term stability of 1.5×10−11~τ−1/2 is demonstrated, in reasonable agreement with predictions from the signal-to-noise ratio of the measured Ramsey fringes. The cavity-grating package has a volume of ≈67~cm\textsuperscript{3}, ensuring an inherently compact system while the use of a GMOT drastically simplifies the optical requirements for laser cooled atoms. This work is another step towards the realisation of highly compact portable cold-atom frequency standards.

Vignette d'image
Publication
Accès libre

GNSS-grade space atomic frequency standards: Current status and ongoing developments

2021, Batori, Etienne, Almat, Nil, Affolderbach, Christoph, Mileti, Gaetano

We present an overview on the current state of Global Navigation Satellite Systems (GNSS)-grade or better space atomic frequency standards’ (SAFS) technologies and discuss their applications. We estimate that a total of more than 1000 such standards were sent to space so far, the vast majority consisting of rubidium-cell frequency standards, Cs atomic beam frequency standards, and passive hydrogen masers. Finally, we review a variety of ongoing developments in view of future new generations of GNSS-grade SAFSs.

Vignette d'image
Publication
Accès libre

Impact of microwave-field inhomogeneity in an alkali vapour cell using Ramsey double-resonance spectroscopy

2019, Moreno, William, Pellaton, Matthieu, Affolderbach, Christoph, Almat, Nil, Gruet, Florian, Mileti, Gaetano

We numerically and experimentally evaluate the impact of the inhomogeneity of the microwave field in the cavity used to perform double-resonance (DR) Ramsey spectroscopy in a buffer gas alkali vapour cell. The Ramsey spectrum is numerically simulated using a simple theoretical model and taking into account the field distribution in a magnetron-type microwave resonator. An experimental evaluation is performed using a DR pulsed optically pumped (POP) atomic clock. It is shown that the sensitivity to the micro-wave power of the DR POP clock can be reproduced from the combination of two inhomogeneities across the vapour cell: microwave field inhomogeneity and atomic ground-state resonance frequency inhomogeneity. Finally, we present the existence of an optimum operation point for which the microwave power sensitivity of our DR POP clock is reduced by two orders of magnitude. It leads into a long-term frequency stability of 1 × 10-14.

Vignette d'image
Publication
Accès libre

Rb vapor-cell clock demonstration with a frequency-doubled telecom laser

2018, Almat, Nil, Pellaton, Matthieu, Moreno, William, Gruet, Florian, Affolderbach, Christoph, Mileti, Gaetano

We employ a recently developed laser system, based on a low-noise telecom laser emitting around 1.56 μm, to evaluate its impact on the performance of an Rb vapor-cell clock in a continuous-wave double-resonance scheme. The achieved short-term clock instability below 2.5·10−13·τ−1∕2 demonstrates, for the first time, the suitability of a frequency-doubled telecom laser for this specific application. We measure and study quantitatively the impact of laser amplitude and frequency noises and of the ac Stark shift, which limit the clock frequency stability on short timescales. We also report on the detailed noise budgets and demonstrate experimentally that, under certain conditions, the short-term stability of the clock operated with the low-noise telecom laser is improved by a factor of three compared to clock operation using the direct 780-nm laser.

Vignette d'image
Publication
Accès libre

An additive-manufactured microwave cavity for a compact cold-atom clock

2023, Batori, Etienne, Alan Bregazzi, Ben Lewis, Paul F. Griffin, Erling Riis, Mileti, Gaetano, Affolderbach, Christoph

We present an additive-manufactured microwave cavity for a Ramsey-type, double resonance, compact cold-atom clock. Atoms can be laser cooled inside the cavity using a grating magneto-optic trap with the cavity providing an excellent TE011-like mode while maintaining sufficient optical access for atomic detection. The cavity features a low Q-factor of 360 which conveniently reduces the cavity pulling of the future clock. Despite the potential porosity of the additive-manufacturing process, we demonstrate that the cavity is well-suited for vacuum. A preliminary clock setup using cold atoms allows for measuring the Zeeman spectrum and Rabi oscillations in the cavity which enables us to infer excellent field uniformity and homogeneity, respectively, across the volume accessed by the cold atoms. Ramsey spectroscopy is demonstrated, indicating that the cavity is suitable for clock applications. Finally, we discuss the limitations of the future clock.

Vignette d'image
Publication
Accès libre

Long-Term Stability Analysis Towards <10-14 Level for a Highly Compact POP Rb Cell Atomic Clock

2020, Almat, Nil, Gharavipour, Mohammadreza, Moreno, William, Gruet, Florian, Affolderbach, Christoph, Mileti, Gaetano

Long-term frequency instabilities in vapor-cell clocks mainly arise from fluctuations of the experimental and environmental parameters that are converted to clock frequency fluctuations via various physical processes. Here, we discuss the frequency sensitivities and the resulting stability limitations at one-day timescale for a rubidium vapor-cell clock based on a compact magnetron-type cavity operated in air (no vacuum environment). Under ambient laboratory conditions, the external atmospheric pressure fluctuations may dominantly limit the clock stability via the barometric effect. We establish a complete longterm instability budget for our clock operated under stable pressure conditions. Where possible, the fluctuations of experimental parameters are measured via the atomic response. The measured clock instability of <2 × 10-14 at one day is limited by the intensity light-shift effect, which could further be reduced by active stabilization of the laser intensity or stronger optical pumping. The analyses reported here show the way toward simple, compact, and low-power vapor-cell atomic clocks with excellent long-term stabilities ≤10-14 at one day when operated in ambient laboratory conditions.

Vignette d'image
Publication
Accès libre

3D printed microwave cavity for atomic clock applications: proof of concept

2018-6-7, Pellaton, Matthieu, Affolderbach, Christoph, Mileti, Gaetano, Skrivervik, A.K., Ivanov, A.E., Debogovic, T., de Rijk, E.

The authors present the realisation and characterisation of an additively manufactured (AM) microwave resonator cavity for double-resonance (DR) vapour-cell atomic clocks. The design of the compact microwave cavity is based on the loop-gap resonator approach, previously demonstrated for conventionally-machined aluminium components. In the present study, the resonator is fabricated by AM using a metal-coated polymer. A resonance frequency at the desired 6.835 GHz rubidium atomic frequency is obtained. When employed in an atomic clock setup, the AM cavity enables a DR signal of <;500 Hz linewidth and of nearly 20% contrast, thus fulfilling the stringent requirements for DR atomic clocks. A clock short-term stability of 1 × 10 -12 τ -1/2 is demonstrated, comparable to state-of-the-art clock performances.

Vignette d'image
Publication
Accès libre

A Microcell Atomic Clock Based on a Double-Resonance Ramsey Scheme

2022, Batori, Etienne, Affolderbach, Christoph, Pellaton, Matthieu, Gruet, Florian, Maddalena Violetti, Yuanyan Su, Anja K. Skrivervik, Mileti, Gaetano

Pas de vignette d'image disponible
Publication
Métadonnées seulement

Long-Term Stability Analysis Towards < 10-14 Level for a Highly Compact POP Rb Cell Atomic Clock

2019-4-14, Almat, Nil, Gharavipour, Mohammadreza, Moreno, William, Affolderbach, Christoph, Mileti, Gaetano

Long-term frequency instabilities in vapor-cell clocks mainly arise from fluctuations of the experimental and environmental parameters that are converted to clock frequency fluctuations via various physical processes. Here, we discuss the frequency sensitivities and the resulting stability limitations at one day timescale for a rubidium vapor-cell clock based on a compact magnetron-type cavity operated in air (no vacuum environment). Under ambient laboratory conditions, the external atmospheric pressure fluctuations may dominantly limit the clock stability via the barometric effect. We establish a complete long-term instability budget for our clock operated under stable pressure conditions. Where possible, the fluctuations of experimental parameters are measured via the atomic response. The measured clock instability of < 2·E10.14 at one day is limited by the intensity light-shift effect, which could further be reduced by active stabilization of the laser intensity or stronger optical pumping. The analyses reported here show the way towards simple, compact, and low-power vapor-cell atomic clocks with excellent long-term stabilities. ≤ 10.14 at one day when operated in ambient laboratory conditions.

Pas de vignette d'image disponible
Publication
Métadonnées seulement

Barometric Effect in Vapor-Cell Atomic Clocks

2018-6-4, Moreno, William, Pellaton, Matthieu, Affolderbach, Christoph, Mileti, Gaetano

Vapor-cell atomic clocks are compact and high-performance frequency references employed in various appli-cations ranging from telecommunication to global positioningsystems. Environmental sensitivities are often the main sourcesof long-term instabilities of the clock frequency. Among thesesensitivities, the environmental pressure shift describes the clockfrequency change with respect to the environmental pressurevariations. We report here on our theoretical and experimentalanalysis of the environmental pressure shift on rubidium atomicfrequency standards (RAFSs) operated under open atmosphere.By using an unsealed high-performance laser-pumped rubidiumstandard, we demonstrate that the deformation of the vapor-cell volume induced by the environmental pressure changes(i.e., barometric effect) is the dominant environmental pressureshift in a standard laboratory environment. An experimentalbarometric coefficient of 8.2×10−14/hPa is derived, in goodagreement with theory and with previously reported measure-ments of frequency shifts of RAFS operated when transiting tovacuum.